Analog Parameters Set Using QSF Assignments

19

2015.01.19

UG-01080

Subscribe

Send Feedback

You specify the analog parameters using the Quartus II Assignment Editor, the Pin Planner, or through

the Quartus II Settings File (.qsf). The default values for analog options fall into three categories:
Global— These parameters have default values that are independent of other parameter settings.

Computed—These parameters have an initial default value that is recomputed based on other

parameter settings.

Proxy—These parameters have default values that are place holders. The Quartus II software selects

these initial default values based on your design; however, Altera recommends that you replace these

defaults with values that match your electrical board specification.

For more information about the Pin Planner, refer to About the Pin Planner in Quartus II Help. For more

information about the Assignment Editor, refer to About the Assignment Editor in Quartus II Help.
For more information about Quartus II Settings, refer to Quartus II Settings File Manual.

Related Information

About the Pin Planner

About the Assignment Editor

Quartus II Settings File Manual

Making QSF Assignments Using the Assignment Editor

The Quartus II software provides default values for analog parameters. You can change the default values

using the Assignment Editor. For example, complete the following steps to specify a 3.0V supply for the

VCCA voltage and a 1.0V supply to the VCCR voltages.
1. On the Assignments menu, select Assignment Editor. The Assignment Editor appears.

2. Complete the following steps for each pin requiring the VCCA voltage:

a. Double-click in the Assignment Name column and scroll to the bottom of the available

assignments.

b. Select VCCA_GXB Voltage.

c. In the Value column, select 3_0V from the list.

3. Complete the following steps for each pin requiring the VCCR voltage:

©

2015 Altera Corporation. All rights reserved. ALTERA, ARRIA, CYCLONE, ENPIRION, MAX, MEGACORE, NIOS, QUARTUS and STRATIX words and logos are

trademarks of Altera Corporation and registered in the U.S. Patent and Trademark Office and in other countries. All other words and logos identified as

trademarks or service marks are the property of their respective holders as described at

www.altera.com/common/legal.html

. Altera warrants performance

of its semiconductor products to current specifications in accordance with Altera's standard warranty, but reserves the right to make changes to any

products and services at any time without notice. Altera assumes no responsibility or liability arising out of the application or use of any information,

product, or service described herein except as expressly agreed to in writing by Altera. Altera customers are advised to obtain the latest version of device

specifications before relying on any published information and before placing orders for products or services.

ISO

9001:2008

Registered

www.altera.com

101 Innovation Drive, San Jose, CA 95134