Simulation support, Simulation support -34 – Altera Transceiver PHY IP Core User Manual
Page 517

For non-bonded clocks, each channel and each TX PLL has a separate dynamic reconfiguration interfaces.
The MegaWizard Plug-In Manager provides informational messages on the connectivity of these
interfaces. The following example shows the messages for the Cyclone V Native PHY with four duplex
channels, four TX PLLs, in a nonbonded configuration.
For more information about transceiver reconfiguration refer to Transceiver Reconfiguration Controller
IP Core.
Example 15-4: Informational Messages for the Transceiver Reconfiguration Interface
PHY IP will require 8 reconfiguration interfaces for connection to the
external reconfiguration controller.
Reconfiguration interface offsets 0-3 are connected to the transceiver
channels.
Reconfiguration interface offsets 4–7 are connected to the transmit PLLs.
Related Information
Simulation Support
The Quartus II release provides simulation and compilation support for the Native PHY IP Core. Refer to
Running a Simulation Testbench for a description of the directories and files that the Quartus II software
creates automatically when you generate your Native PHY IP Core.
Related Information
Running a Simulation Testbench
15-34
Simulation Support
UG-01080
2015.01.19
Altera Corporation
Cyclone V Transceiver Native PHY IP Core Overview