beautypg.com

10gbase-r phy interfaces, 10gbase-r phy interfaces -13 – Altera Transceiver PHY IP Core User Manual

Page 37

background image

Name

Value

Description

Receiver common mode

voltage

Tri-State
0.82V
1.1v

Specifies the RX common mode voltage.

Receiver termination

resistance

OCT_85_OHMS
OCT_100_OHMs
OCT_120_OHMS
OCT_150_OHMS

Indicates the value of the termination resistor for

the receiver.

Receiver DC

0-4

Sets the equalization DC gain using one of the

following settings:
• 0: 0 dB

• 1: 3 dB

• 2: 6 dB

• 3: 9 dB

• 4: 12 dB

Receiver static equalizer

setting:

0-15

This option sets the equalizer control settings. The

equalizer uses a pass band filter. Specifying a low

value passes low frequencies. Specifying a high

value passes high frequencies.

Analog Parameters for Arria V, Arria V GZ, and Stratix V Devices

Click on the appropriate links to review the analog parameters for these devices.

Related Information

Analog Settings for Arria V Devices

on page 19-2

Analog Settings for Arria V GZ Devices

on page 19-11

Analog Settings for Stratix V Devices

on page 19-34

10GBASE-R PHY Interfaces

This section describes the 10GBASE-R PHY interfaces.
The following figure illustrates the top-level signals of the 10BASE-R PHY; <n> is the channel number.

UG-01080

2015.01.19

10GBASE-R PHY Interfaces

3-13

10GBASE-R PHY IP Core

Altera Corporation

Send Feedback