beautypg.com

Word alignment parameters, Word alignment parameters -7 – Altera Transceiver PHY IP Core User Manual

Page 220

background image

Name

Value

Description

Enable embedded reset

control

On/Off

When On, the automatic reset controller initiates the

reset sequence for the transceiver. When Off you can

design your own reset logic using

tx_analogreset

,

rx_analogreset

,

tx_digitalreset

,

rx_digital-

reset

, and

pll_powerdown

which are top-level ports

of the Custom Transceiver PHY. You may also use

the Transceiver PHY Reset Controller' to reset the

transceivers. For more information, refer to the

Transceiver Reconfiguration Controller IP Core . By

default, the CDR circuitry is in automatic lock mode

whether you use the embedded reset controller or

design your own reset logic. You can switch the CDR

to manual mode by writing the

pma_rx_setlockto-

data

or

pma_rx_set_locktoref

registers to 1. If

either the

pma_rx_set_locktodata

and

pma_rx_

set_locktoref

is set, the CDR automatic lock mode

is disabled.

Table 9-4: Reset Mode

The CDR can be put in either manual or automatic mode. The CDR mode is controlled with the

pma_rx_set_locktodata

and

pma_rx_set_locktoref

registers. This table shows the required settings to control

the CDR mode.

rx_set_locktoref

rx_set_locktodata

CDR Lock Mode

1

0

Manual RX CDR locked to reference

X

1

Manual RX CDR locked to data

0

0

Automatic RX CDR

Related Information

Transceiver Reset Control in Stratix V Devices

Word Alignment Parameters

The word aligner restores word boundaries of received data based on a predefined alignment pattern. This

pattern can be 7, 8, 10, 16, 20, or 32 bits long. The word alignment module searches for a programmed

pattern to identify the correct boundary for the incoming stream.

UG-01080

2015.01.19

Word Alignment Parameters

9-7

Custom PHY IP Core

Altera Corporation

Send Feedback