Name

Value

Description

VMINRULE

0-63

Specifies the minimum V

OD

. The default value is 9

which represents 165 mV.

VODMINRULE

0-63

Specifies the minimum V

OD

for the first tap. The

default value is 22 which represents 440mV.

VPOSTRULE

0-31

Specifies the maximum value that the internal

algorithm for pre-emphasis will ever test in

determining the optimum post-tap setting. The

default value is 25.

VPRERULE

0-15

Specifies the maximum value that the internal

algorithm for pre-emphasis will ever test in

determining the optimum pre-tap setting. The

default value is 15.

PREMAINVAL

0-63

Specifies the Preset V

OD

Value. Set by the Preset

command as defined in Clause 72.6.10.2.3.1 of the

link training protocol. This is the value from which

the algorithm starts. The default value is 60.

PREPOSTVAL

0-31

Specifies the preset Pre-tap Value. The default value

is 0.

PREPREVAL

0-15

Specifies the preset Post-tap value. The default value

is 0.

INITMAINVAL

0-63

Specifies the Initial VOD Value. Set by the Initialize

command in Clause 72.6.10.2.3.2 of the link training

protocol. The default value is 35.

INITPOSTVAL

0-31

Specifies the initial first Post-tap value. The default

value is 14.

INITPREVAL

0-15

Specifies the Initial Pre-tap Value. The default value

is 3.