Figure 15-6. One TDM Channel with Shadow RAM for Dynamic Route Change
This configuration should be chosen when only one TDM is needed, but dynamic rerouting may be needed
on that TDM. Similarly, for two TDM channels, the number of SIx RAM entries are reduced for every
TDM channel programmed for shadow mode.
15.4.3
Programming SI
x
RAM Entries
The programming of each entry in the SIx RAM determines the routing of the serial bits (or bit groups)
and the assertion of strobe outputs. If MCC is set, the entry refers to the corresponding MCC; otherwise,
it refers to other serial controllers.
shows the entry fields for both cases.
The use of MCC slots is restricted for slots with lengths up to a single byte. For channels, that require more
than a single byte, superchannel or slot splitting is mandatory.
When MCC = 0, the SIx RAM entry fields function as described in
.
0
1
2
3
4
5
6
7
10
11
13
14
15
Field MCC = 0
SWTR
SSEL1
SSEL2 SSEL3 SSEL4
0
CSEL
CNT
BYT LST
MCC = 1 LOOP/ECHO
SUPER
MCSEL
CNT
BYT LST
R/W
R/W
Addr
See
Figure 15-7. SI
x RAM Entry Fields
128 Entries
TXa
Route
Framing Signals
L1TCLKa
x
L1TSYNCa
x
SI
x
RAM Address:
128 Entries
RXa
Route
255
1279
1024
L1RCLKa
x
L1RSYNCa
x
1280
256
511
1535
(each entry is 16 Bits Wide)
0