Inverse Multiplexing for ATM (IMA)

MPC8260 PowerQUICC II Family Reference Manual, Rev. 2

Freescale Semiconductor

33-35

0x18

LINK 11 INFO

Byte

Status and control of link with LID = 11

0x19

LINK 10 INFO

Byte

Status and control of link with LID = 10

0x1A

LINK 9 INFO

Byte

Status and control of link with LID = 9

0x1B

LINK 8 INFO

Byte

Status and control of link with LID = 8

0x1C

LINK 15 INFO

Byte

Status and control of link with LID = 15

0x1D

LINK 14 INFO

Byte

Status and control of link with LID = 14

0x1E

LINK 13 INFO

Byte

Status and control of link with LID = 13

0x1F

LINK 12 INFO

Byte

Status and control of link with LID = 12

0x20

LINK 19 INFO

Byte

Status and control of link with LID = 19

0x21

LINK 18 INFO

Byte

Status and control of link with LID = 18

0x22

LINK 17 INFO

Byte

Status and control of link with LID = 17

0x23

LINK 16 INFO

Byte

Status and control of link with LID = 16

0x24

LINK 23 INFO

Byte

Status and control of link with LID = 23

0x25

LINK 22 INFO

Byte

Status and control of link with LID = 22

0x26

LINK 21 INFO

Byte

Status and control of link with LID = 21

0x27

LINK 20 INFO

Byte

Status and control of link with LID = 20

0x28

LINK 27 INFO

Byte

Status and control of link with LID = 27

0x29

LINK 26 INFO

Byte

Status and control of link with LID = 26

0x2A

LINK 25 INFO

Byte

Status and control of link with LID = 25

0x2B

LINK 24 INFO

Byte

Status and control of link with LID = 24

0x2C

LINK 31 INFO

Byte

Program to 0x00.

0x2D

LINK 30 INFO

Byte

Status and control of link with LID = 30

0x2E

LINK 29 INFO

Byte

Status and control of link with LID = 29

0x2F

LINK 28 INFO

Byte

Status and control of link with LID = 28

0x30

CRC10

Hword

Microcode-managed area. Microcode will program this field
dynamically.

0x32

END-TO-END
CHANNEL

Byte

Program to any value desired for end-to-end
implementation-dependent signalling, or program to 0x00 if unused.

0x33

UNUSED

Byte

Program to 0x6A.

0x34

TAG

Byte

Internally-used tag value indicating that this is an ICP cell. Program to
0x80.

1

Boldfaced entries in the above table indicate parameters which must be initialized by the user. All other
parameters are managed by the microcode and should be initialized to zero unless otherwise stated.

Table 33-9. ICP Cell Template (continued)

1

Offset

Name

Width

Description