Brocade Network Advisor SAN + IP User Manual v12.1.0 User Manual
Page 2142
Brocade Network Advisor SAN + IP User Manual
2105
53-1002949-01
Database tables and fields
I
TABLE 227
HBA
Field
Definition
Format
Size
ID
Unique generated database identifier. int
HOST_ID
ID of the Device Enclosure (Host) to
which this HBA belongs to.
int
NAME
User defined name of the HBA
varchar
128
POWER_MODE
Power mode of the HBA
varchar
256
MODEL
Model code of the HBA
varchar
256
MODEL_DESCRIPTION
Model description for the HBA
varchar
256
OPERATING_STATUS
Current operating status of the HBA:
1: Enabled/0: Disabled.
The default value is 0.
smallint
CHIP_REVISION
Revision level of the chip used in the
HBA
varchar
64
HARDWARE_PATH
Hardware path for the HBA.
varchar
256
SERIAL_NUMBER
Serial number of the HBA
varchar
64
TEMPERATURE
Temperatur of HBA. Both in
Celsius/Fahrenheit
varchar
16
USERNAME
User name to be used for logging into
the HBA.
varchar
256
PASSWORD
Password used for logging into the
HBA
varchar
256
MANAGEMENT_STATE
Management state bit mask,
Managed/Auth failed etc.
The default value is -1.
int
MANAGEMENT_INTERFACE
Management interface bit mask,
JSON/WMI/SMI etc . The default
value is -1.
int
DRIVER_VERSION
The version level of the host adapter
driver
varchar
256
DRIVER_NAME
The name of the HBA driver
varchar
256
FIRMWARE_VERSION
The version level of the firmware
varchar
256
BIOS_VERSION
The version level of the BIOS
varchar
256
PCI_REG_VENDOR_ID
The identifier of the PCI Register''s
vendor
varchar
32
PCI_REG_DEVICE_ID
The device ID of the PCI Register
varchar
32
PCI_REG_SUBSYSTEM_ID
The ID of the PCI subsystem
varchar
32
PCI_REG_SUBSYS_VENDOR_ID The ID of the PCI subsystem vendor.
varchar
32
PCI_REG_LANE_COUNT
The number of PCI lanes, in Gbps,
each way between the PCI slot and
the adapter. The default value is 8.
int