1102
Brocade Network Advisor SAN + IP User Manual
53-1002949-01
FCIP trunking
27
•
Consider available WAN bandwidth requirements when configuring failover circuit groups.
Refer to
“Bandwidth calculation during failover”
Examples of circuit failover in groups
Tables
Table 117
through
Table 119
provide examples of how failover occurs on circuits with
different bandwidths configured in failover groups.
Table 117
illustrates circuit failover in a tunnel with two failover groups, each with two circuits. All
data through the tunnel is initially load balanced over Circuits 1 and 2. The following occurs during
circuit failover:
•
If circuit 1 fails, circuit 3 becomes active and data is load balanced over circuit 2 and 3.
•
If circuit 2 fails, circuit 4 becomes active and data is load balanced over circuit 1 and 4.
•
If both circuit 1 and 2 fail, circuit 3 and.4 become active and data is load balanced over both
circuits.
Table 118
illustrates circuit failover in a tunnel with one failover group containing three circuits, In
this case, failover occurs as if circuits are not part of a failover group. Circuit 2 and 3, both with
metric 1, become active only after circuit 1 with metric 0 fails.
Table 119
illustrates circuit failover in a tunnel with circuits in failover groups and circuits that are
not part of failover groups. In this configuration, all data is initially load balanced over circuit.1,
circuit 2, and circuit 3 (when they are all active). The following occurs during circuit failover:
•
If circuit1 fails, circuit 4 becomes active and data is load balanced over circuit 2, circuit 3, and
circuit 4.
Reason: Circuit 1 fails over to circuit 4 (both are in failover group 1) and circuit 3 is active with
500Mb bandwidth.
TABLE 117
Tunnel with two failover groups with two circuits
Circuits in tunnel
Failover group ID
Circuit bandwidth
In use for tunnel data
Circuit 1
Metric 0
1
500Mb
If active, yes.
Circuit 2
Metric 0
2
1000Mb
If active, yes.
Circuit 3
Metric 1
1
500Mb
Only when circuit 1
fails.
Circuit 4
Metric 1
2
1000Mb
Only when circuit 2
fails.
TABLE 118
Tunnel with one failover groups with three circuits
Circuits in tunnel
Failover group ID
Circuit bandwidth
In use for tunnel data
Circuit 1
Metric 0
1
1000Mb
If active, yes.
Circuit 2
Metric 1
1
500Mb
Only when circuit 1
fails.
Circuit 3
Metric 1
1
500Mb
Only when circuit 1
fails.