Port connectivity, Port connectivity 8 – Brocade Network Advisor SAN + IP User Manual v12.1.0 User Manual
Page 1664
1618
Brocade Network Advisor SAN + IP User Manual
53-1002949-01
Accessing Flow Vision from other management application features
44
describes how options are populated on the Add Flow Definition dialog box are
populated according to the row selected on the Reverse Route tab,
Port connectivity
Select a port from the Port Connectivity View dialog box and select Add Flow to launch the Add Flow
Definition dialog box. Use this dialog box to define a flow between the source and destination
devices.
describes how options are populated on the Add Flow Definition dialog box are
populated according to the row selected on the Reverse Route tab,
TABLE 161
Add Flow Definition dialog box options populated per Reverse Route selection
Port Selected
Options populated
No rows
selected
Source Device = Source ID from source device port
Destination Device = Destination ID from destination device port.
Target Switch = Switch in selected row.
Direction = Bidirectional
If first row is
selected (where
In Port Address
is destination
device port's
connected
switch port
address)
Source Device = * if port is on a 16-Gbps switch, otherwise empty.
Destination Device = Device ID from destination device port.
Ingress Port = ‘In’ port slot/port of selected row.
Target Switch = Switch of selected row.
Direction = Bidirectional
If last row is
selected (where
Out Port Address
is source device
port’s connected
switch port
address)
Source Device = Source ID from source device port.
Destination Device = * if port is on a 16-Gbps switch, otherwise empty.
Ingress Port = ‘Out’ port slot/port of selected row.
Target Switch = Switch of selected row.
Direction = Bidirectional
If selected row is
neither the first
or last row.
Source Device = * if port is on a 16-Gbps switch, otherwise empty.
Destination Device = * if port is on a 16-Gbps switch, otherwise empty.
Ingress Port = ‘In’ port slot/port of selected row.
Target Switch = Switch of selected row.
Direction = Bidirectional
TABLE 162
Add Flow Definition dialog box options populated per Reverse Route selection
Row Selected
Options populated
E_Port
Source Device = * if port is on a 16-Gbps switch, otherwise empty.
Destination Device = * if port is on a 16-Gbps switch, otherwise empty.
Target Switch = Selected switch.
Direction = Bidirectional
Initiator
Source Device = Initiator port ID.
Destination Device = * if port is on a 16-Gbps switch, otherwise empty.
Ingress Port = Selected port's connected switch port number.
Target Switch = Selected port's connected switch.
Direction = Bidirectional