Resolving merge conflicts – Brocade Network Advisor SAN + IP User Manual v12.1.0 User Manual
Page 1252
Brocade Network Advisor SAN + IP User Manual
1201
53-1002949-01
Cascaded FICON fabric merge
30
Resolving merge conflicts
You can resolve the following types of switch configuration conflicts:
•
Domain ID
•
TOV
•
Buffer To Buffer Credit
•
Disable Device Probe
NOTE
This test will be skipped if all primary and secondary fabric switches are found to be Fabric OS
7.0 and later.
•
Route Priority Per Frame
•
Sequence Level Switching
•
Suppress Class F
•
Long Distance Setting
•
Data Field Size
•
VC Priority
Note that not all tests support resolution. If a test supports resolution, the Description column
contains the text “Resolvable”.
To resolve merge conflicts, complete the following steps.
1. Select the failed test where the Description column contains the text “Resolvable”.
2. Click Resolve.
A “The switches in fabric Name will be disabled prior to making the configuration change. The
switches will be reenabled after the configuration changes are applied. Please confirm to
proceed.” warning message displays.
3. Click OK on the warning message.
The values of the fabric chosen on the Set up merge options screen are applied to all devices
in the second fabric. Once the settings are applied, the test is run again and the merge results
are updated.
.
If an error occurs, an error message displays. You must use Web Tools or the CLI to resolve this
conflict. Click OK on the error message and go to
.
If you are resolving a domain ID error, there may be multiple switches involved. If multiple
switches have the domain ID error, the Configure Domain IDs dialog box displays listing all
devices that have the domain ID conflict.
a. Select the device for which you want to resolve the domain ID in the Available Switches list
and click the right arrow button.
b. Select a new domain ID for the device from the Domain ID list.
c. Repeat steps a and step b for each device in the Available Switches list.
d. Click OK on the Configure Domain IDs dialog box.
4. Repeat
through
until all resolvable tests pass.