Page 655
6 RLC Swept SA Measurement Front-Panel & SCPI Reference
Input/Output
Gate
Selects the gate signal to be output to the Trig 1 Out or Trig 2 Out connector. The gate signal has
been delayed and its length determined by delay and length settings. When the polarity is
positive, a high on the Trig 1 Out or Trig 2 Out represents the time the gate is configured to pass
the signal.
Key Path
Input/Output, Output Config, Trig 1/2 Output
Example
TRIG1:OUTP GATE
Readback
Gate
Initial S/W Revision
Prior to A.02.00
Odd/Even Trace Point
Selects either the odd or even trace points as the signal to be output to the Trig 1 Out or Trig 2
Out connector when performing swept spectrum analysis. When the polarity is positive, this
output goes high during the time the analyzer is sweeping past the first point (Point 0) and every
other following trace point. The opposite is true if the polarity is negative.
Key Path
Input/Output, Output Config, Trig 1/2 Output
Example
TRIG1:OUTP OEV
Readback
Odd/Even
Initial S/W Revision
Prior to A.02.00
Analog Out
This menu lets you control which signal is fed to the “Analog Out” connector on the analyzer rear
panel.
See
"More Information" on page 656
Key Path
Input/Output, Output Config
Remote Command
:OUTPut:ANALog OFF|SVIDeo|LOGVideo|LINVideo|DAUDio
:OUTPut:ANALog?
Example
OUTP:ANAL SVIDeo ! causes the analog output type to be Screen Video
Preset
OFF
Preset
This is unaffected by Preset but is set to DAUDio on a "Restore Input/Output Defaults" or
"Restore System Defaults->All
Remote Language Compatibility Measurement Application Reference