Meanpwr (mean power measurement), Syntax, Legacy products – Agilent Technologies Signal Analyzer N9030a User Manual
Page 376: Description, Syntax legacy products
5 Legacy Command Descriptions
MEANPWR (Mean Power measurement)
MEANPWR (Mean Power measurement)
Syntax
Legacy Products
8560 series
Description
Measures the average power of the carrier during that portion of the time when it is on. The on
state is defined as the time when the signal is within a selected number of dB of its peak level.
The range of amplitudes that is defined as the on state can be set with the command. The
amplitude range is set relative to the peak value of the signal.
Format
MEANPWR TRA|TRB,
Range: 0.01 dB to 100 dB
Query Data Type
SCPI Equivalent Commands
None
Notes
MEANPWR
is similar to
"CARRON (Carrier On Power)" on page 256
, except that CARRON
defines ‘on’ as that time when the signal is within 20 dB of its peak level.
376
Remote Language Compatibility Measurement Application Reference