Agilent Technologies Signal Analyzer N9030a User Manual
Page 1040
![background image](/manuals/40104/1040/background.png)
6 RLC Swept SA Measurement Front-Panel & SCPI Reference
Save
Line
#
Type of field
Example
Notes
“Amplitude Correction”
2
File Description (in quotes)
“Correction Factors for 11966E”
60 characters max; may be empty but
may not be omitted. If exceeds 60
characters, error –233 Too much data
reported
3
Comment (in quotes)
“Class B Radiated”
60 characters max; may be empty but
may not be omitted. . If exceeds 60
characters, error –233 Too much data
reported
4
Instrument Version, Model
#
A.02.06,N9020A
May be empty but may not be omitted
5
Option List, File Format
Version
K03 LFE EXM ,01
May be empty but may not be omitted
6
Freq Unit to be used for all
frequency values in the file
Frequency Unit,MHz
assumed to be Hz if omitted
7
Antenna Unit
Antenna Unit,None
If omitted leaves the Antenna unit
unchanged. The amplitude unit in the
Antenna Unit field is a conversion
factor that is used to adjust the Y Axis
Units of the current mode, if the mode
supports Antenna Units. For more
details on antenna correction data, refer
to the Input/Output,Corrections key
description. Allowable values:
dBuv/m, dBuA/m, dBG, dBpT, None
8
Freq Interpolation
Frequency Interpolation,Linear
if omitted leaves the Freq Interpolation
unchanged. Allowable values: Linear,
Logarithmic
9
Bias value in mA
Bias,0.00
If omitted leaves the Bias value
unchanged (added as of A.08.50)
10
Bias State
Bias State,On
If omitted leaves the Bias State
unchanged. Allowable values: On, Off
(added as of A.08.50)
11
Overlap, two values, Freq1
and Freq2, separated by
commas.
Overlap,33500,40000
Uses Freq Unit from line 6. Thus, in
this example Freq1=33.5 GHz, Freq2=
40.0 GHz (see note below). If omitted
leaves the overlap unchanged (added as
of A.08.50)
12
DATA marker
DATA
Corrections data begins in the next line
1040