RCLS (Recall State)
RCLS (Recall State)
Syntax
Legacy Products
8560 series, 8566A/B, 8568A/B
Description
Recalls instrument state data from the specified state register in the instrument’s memory.
l
Registers 1 through 6 are reserved for the user, and contain instrument states (such as front
panel configuration) saved with
"SAVES (Save State)" on page 458
or
l
Option LAST: recalls the instrument state that existed previous to executing the IP command
or switching the instrument off. 8566/8 instruments use register 7 for this purpose.
l
Option PWRON: sets the instrument state to the same state that occurred when the instrument
was switched on. This state was originally saved using SAVES.
Format
RCLS
Range: 1-6
RCLS LAST|PWRON
See Description above.
Query Data Type
N/A
SCPI Equivalent Commands
*RCL
"Recall Instrument State " on page 107
Notes
The functions of RCLS are identical to
"RC (Recall State)" on page 445
.
Remote Language Compatibility Measurement Application Reference