Mkpk (marker peak), Syntax, Legacy products – Agilent Technologies Signal Analyzer N9030a User Manual
Page 398: Description, Mkpk (marker peak)" on, Syntax legacy products
5 Legacy Command Descriptions
MKPK (Marker Peak)
MKPK (Marker Peak)
Syntax
Legacy Products
8560 series, 8566A/B, 8568A/B
Description
Executing MKPK HI, or simply MKPK (no secondary keyword), positions the active marker at the
highest signal detected. If an active marker is on the screen, the MKPK parameters move the
marker as follows:
HI (highest)
Moves the active marker to the highest peak.
NH (next highest)
Moves the active marker to the next signal peak of lower amplitude.
NR (next right)
Moves the active marker to the next signal peak to the right of the current marker.
NL (next left)
Moves the active marker to the next signal peak to the left of the current marker.
Format
MKPK [HI]|NH|NR|NL
Query Data Type
N/A
SCPI Equivalent Commands
:CALCulate:MARKer[1]|2:MAXimum
:CALCulate:MARKer[1]|2:MAXimum:NEXT
:CALCulate:MARKer[1]|2:MAXimum:LEFT|RIGHt
(See
Notes
The functions of MKPK (no secondary keyword) and MKPK HI are identical to
For 8566A/B, 8568A/B, the functions of MKPK NH are similar to
398
Remote Language Compatibility Measurement Application Reference