6 RLC Swept SA Measurement Front-Panel & SCPI Reference
Sweep/Control
Backwards
Compatibility SCPI
:TRIGger[:SEQuence]:EXTernal:LEVel
For backward compatibility, the parameter EXTernal is mapped to EXTernal1
Backwards
Compatibility SCPI
:TRIGger[:SEQuence]:FRAMe:EXTernal1:LEVel
Initial S/W Revision
Prior to A.02.00
Trig Slope
Controls the trigger polarity. It is set positive to trigger on a rising edge and negative to trigger on
a falling edge.
Key Path
Trigger, External 1
Remote Command
:TRIGger[:SEQuence]:EXTernal1:SLOPe POSitive|NEGative
:TRIGger[:SEQuence]:EXTernal1:SLOPe?
Example
TRIG:EXT1:SLOP NEG
Couplings
This same slope is used in the Ext1 selection for the trigger source in the Trigger menu and for
the period timer sync source (in the Trigger menu and in the Gate Source menu).
Preset
POSitive
State Saved
Saved in instrument state
Backwards
Compatibility SCPI
:TRIGger[:SEQuence]:EXTernal:SLOPe
For backward compatibility, the parameter EXTernal is mapped to EXTernal1
Backwards
Compatibility SCPI
:TRIGger[:SEQuence]:FRAMe:EXTernal1:SLOPe
Backwards Compatibility
Notes
The legacy :TRIGger[:SEQuence]:SLOPe command affects the slopes for the VID, LINE, EXT1,
EXT2, and RFB triggers.
Initial S/W Revision
Prior to A.02.00
External 2
Pressing this key, when it is not selected, selects an external input signal as the trigger. A new
sweep/measurement will start when the external trigger condition is met using the external 2
input connector. The external trigger 2 input connector is on the rear panel.
Pressing this key, when it is already selected, accesses the external 2 trigger setup menu.
Key Path
Trigger
Example
TRIG:SOUR EXT2 Swept SA measurement
1208