Brocade Network OS Command Reference v4.1.0 User Manual
Page 961

Network OS Command Reference
923
53-1003115-01
show media interface
2
Vendor Rev
01
Options
001a Remote fault/Jabber detect/copper link up
Temperature threshold/val
55 Centigrade
Voltage threshold/val
3289.9
(mVolts)
To display SFP information for a 10-gigabit Ethernet interface:
switch# show media interface tengigabitethernet 5/0/1
Interface Ten Gigabit Ethernet 5/0/1
Identifier
3
SFP
Connector
7
LC
Transceiver
0000000000000010 10_GB/s
Name
id
Encoding
6
Baud Rate
103 (units 100 megabaud)
Length 9u
0
(units km)
Length 9u
0
(units 100 meters)
Length 50u
8
(units 10 meters)
Length 62.5u
3
(units 10 meters)
Length Cu
0
(units 1 meter)
Vendor Name
BROCADE
Vendor OUI
00:05:1E
Vendor PN
57-0000075-01
Vendor Rev
A
Wavelength
850 (units nm)
Options
001a Loss_of_Sig,Tx_Fault,Tx_Disable
BR Max
0
BR Min
0
Serial No
AAA108454100431
Date Code
081108
Temperature
44 Centigrade
Voltage
3246.8
(Volts)
Current
0.002
(mAmps)
TX Power
0.1
(uWatts)
RX Power
0.1
(uWatts)
To display SFP information for a Fibre Channel interface:
switch# show media interface fibrechannel 66/0/1
Interface
FibreChannel 66/0/1
Identifier
3
SFP
Connector
7
LC
Transceiver
540c404040000000 200,400,800_MB/s M5,M6 sw Short_dist
Encoding
1
8B10B
Baud Rate
85
(units 100 megabaud)
Length 9u
0
(units km)
Length 9u
0
(units 100 meters)
Length 50u
5
(units 10 meters)
Length 62.5u
2
(units 10 meters)
Length Cu
0
(units 1 meter)
Vendor Name
BROCADE
Vendor OUI
00:05:1e
Vendor PN
57-1000012-01
Vendor Rev
A
Wavelength
850
(units nm)
Options
003a Loss_of_Sig,Tx_Fault,Tx_Disable
BR Max
0
BR Min
0
Serial No
UAF110170000VP1
Date Code
100422