beautypg.com

Vcs rbridge-id (fabric cluster mode) – Brocade Network OS Command Reference v4.1.0 User Manual

Page 1389

background image

Network OS Command Reference

1351

53-1003115-01

vcs rbridge-id (fabric cluster mode)

2

vcs rbridge-id (fabric cluster mode)

Changes the RBridge ID and, optionally, the VCS ID, and can enable logical chassis cluster mode.

Synopsis

vcs rbridge-id rbridge-id [logical-chassis enable | vcsid vcsid [logical-chassis enable]]

Operands

rbridge-id rbridge-id Allows you to change the existing RBridge ID, and gives you the option of

changing the VCS ID at the same time. While changing these IDs, you can
also enable logical chassis cluster mode on the specified RBridge ID.

vcsid vcsid

Changes the VCS ID. The range for this value is 1 to 8192. The default is 1.

logical-chassis enable

Enables logical chassis cluster mode on the switch.

Defaults

None

Command Modes

Privileged EXEC mode

Description

Use this command to change the RBridge ID on a switch. At the same time, you can change the
VCS ID and enable the logical chassis cluster mode for the switch.

Usage Guidelines

Each time you change the Brocade VCS Fabric configuration, the switch resets to the default
configuration and reboots automatically. Make sure to save the configuration before you issue any
of the commands shown in the Synopsis.

To transition a switch from logical chassis cluster mode back to standalone mode, run the
command: no vcs enable

NOTE

Platforms that allow standalone mode are the Brocade VDS 6710-54, 6720, and 6730.

Examples

To convert a node that is in fabric cluster mode to logical chassis cluster mode, while
simultaneously changing its RBridge ID to 10 and its VCS ID to 35:

switch# vcs rbridge-id 10 vcsid 35 logical-chassis enable

See Also

vcs (standalone mode), vcs logical-chassis enable (fabric cluster mode), vcs vcsid (fabric cluster
mode),
vcs (logical chassis cluster mode), vcs virtual ip, vcs config snapshot (logical chassis