beautypg.com

Show bpdu-drop – Brocade Network OS Command Reference v4.1.0 User Manual

Page 734

background image

696

Network OS Command Reference

53-1003115-01

show bpdu-drop

2

show bpdu-drop

Displays information about BPDU guard.

Synopsis

show bpdu-drop [interface {port-channel num| fortygigabitethernet rbridge-id/slot/port |
gigabitethernet rbridge-id/slot/port | tengigabitethernet rbridge-id/slot/port]

Operands

interface

Selects an interface (required).

port-channel num

Selects a port channel interface. The number of available channels range
from 1 through 63 for standalone mode, and from 1 through 6144 for
Brocade VCS Fabric mode. However, the channel can be assigned any
number from 1 through 6144.

fortygigabitethernet

Selects a 40-GbE interface.

gigabitethernet

Selects a 1-GbE interface.

tengigabitethernet

Selects a 10-GbE interface.

rbridge-id/slot/port

Selects the RBridge ID, slot, and port of the respective interface.

Defaults

None

Command Modes

Privileged EXEC mode

Description

Use this command to display information about BPDU Guard.

Usage Guidelines

This command is supported in VCS and standalone mode. This command can be entered on any
RBridge in a Brocade VCS Fabric.

Examples

None

See Also

capture packet interface