beautypg.com

Sflow polling-interval (interface version) – Brocade Network OS Command Reference v4.1.0 User Manual

Page 716

background image

678

Network OS Command Reference

53-1003115-01

sflow polling-interval (interface version)

2

sflow polling-interval (interface version)

Configures the polling interval at the interface level.

Synopsis

sflow polling-interval interval_value

no sflow polling-interval

Operands

interval_value

Specifies a value in seconds to set the polling interval. Valid values range
from 1 through 65535.

Defaults

The defaut is 20.

Command Modes

Interface subtype configuration mode

Description

Use this command to configure the polling interval for an interface. The interval is the maximum
number of seconds between successive samples of counters to be sent to the collector.

Usage Guidelines

Enter no sflow polling interval to return to the default value.

Examples

To set the polling interval to 135 seconds on a specific 40-gigabit Ethernet interface:

switch(config)# interface fortygigabitethernet 1/3/1

switch(conf-if-fo-1/3/1)# sflow polling-interval 135

See Also

interface, sflow polling-interval (global version), sflow enable (interface version),
sflow sample-rate (interface version)