beautypg.com

Show diag burninerrshow – Brocade Network OS Command Reference v4.1.0 User Manual

Page 768

background image

730

Network OS Command Reference

53-1003115-01

show diag burninerrshow

2

show diag burninerrshow

Displays the error messages that are stored in the nonvolatile storage on the slot during the POST
and system verification processes.

Synopsis

show diag burninerrshow [rbridge-id rbridge-id]

Operands

rbridge-id rbridge-id

Specifies the RBridge ID of the switch for which errors stored in the storage
on the slot during POST and system verification are displayed.

Defaults

None

Command Modes

Privileged EXEC mode

Description

Use this command to display errors that are stored in nonvolatile storage on the slot during POST
and system verification.

Usage Guidelines

None

Examples

The error messages are updated when there is a POST failure or a systemVerification failure.
To display burn-in errors from the switch:

switch# show diag burninerrshow rbridge-id 1

errLog for slot M2

errLog is empty for slot M2

errLog for slot S1

errLog is empty for slot S1

errLog for slot S2

errLog is empty for slot S2

errLog for slot S3

errLog is empty for slot S3

errLog for slot L4

errLog is empty for slot L4

rbridgeId 1

See Also

diag burninerrclear, diag clearerror, show diag burninstatus