2

snmp-server sys-descr

Sets the Management Information Base (MIB-2) object identifier (OID) system description.

Synopsis

snmp-server sys-descr string

no snmp-server sys-descr

Operands

string

The text for the system description. The string must be between 4 and
255 characters in length.

Defaults

The system description is “Brocade VDX switch”.

Command Modes

Global configuration mode

Description

Use this command to specify the MIB-2 OID description.

Usage Guidelines

Enter no snmp-server sys-descr to return to the default system description.

Examples

To set the system description OID to “Brocade Cluster switch”:

switch(config)# snmp-server sys-descr “Brocade Cluster switch”

To restore the system description OID to the default:

switch(config)# no snmp-server sys-descr

See Also

show running-config snmp-server, snmp-server community, snmp-server contact,