beautypg.com

Diag turboramtest – Brocade Network OS Command Reference v4.1.0 User Manual

Page 267

background image

Network OS Command Reference

229

53-1003115-01

diag turboramtest

2

diag turboramtest

This test performs a series of low-level structural tests to determine the basic health of the PCI or
PCIe bus and the memories inside the switch ASIC.

Synopsis

diag turboramtest [passcnt count] [slot slot_id}

Operands

passcnt count

Specifies the number of test repetitions. By default, the test runs once.
Valid values range from 1 through 10.

slot slot_id

Specifies the slot ID. This is mandatory for slot-based systems only.

Defaults

The pass count (passcnt) is 1.

Command Modes

Privileged EXEC mode (with the chassis disabled in offline mode).

Description

Use this command to run a memory test of the ASIC chips.

Usage Guidelines

During abnormal termination, the system might be in unusable state. Perform reload to reboot the
chassis or switch to recover.

In slot-based systems, the blade under test undergoes a reset and/or a reinitialization sequence
as part of the cleanup process.

CAUTION

This is a disruptive command. You must disable the chassis and switch before running the test. In
addition, you must reload or fastboot the switch or chassis after the test has completed running.

Examples

In slot-based switches:

switch# diag turboramtest slot S2

% Info: This test should be run to completion. Please do not abort while it is

executing.

Running turboramtest...

Initializing ASIC 0 for BIST

Initializing ASIC 1 for BIST

Initializing ASIC 2 for BIST

turboRamTest on ASIC 0 PASSED

turboRamTest on ASIC 1 PASSED

turboRamTest on ASIC 2 PASSED

turboRamTest on slot S2 PASSED

% Info: Resetting the blade. Please wait till it gets initialized...

completed.

In fixed-configuration switches:

switch# diag turboramtest

% Info: This test should be run to completion. Please do not abort while it is

executing.

Running turboramtest ..............

PASSED.

See Also