981
53-1003115-01
show rbridge-running config
2
system-monitor fan threshold marginal-threshold 1 down-threshold 2
system-monitor fan alert state removed action raslog
system-monitor power threshold marginal-threshold 1 down-threshold 2
system-monitor power alert state removed action raslog
system-monitor temp threshold marginal-threshold 1 down-threshold 2
system-monitor cid-card threshold marginal-threshold 1 down-threshold 2
system-monitor cid-card alert state none action none
system-monitor sfp alert state none action none
system-monitor compact-flash threshold marginal-threshold 1 down-threshold 0
system-monitor MM threshold marginal-threshold 1 down-threshold 0
system-monitor LineCard threshold marginal-threshold 1 down-threshold 2
system-monitor LineCard alert state none action none
system-monitor SFM threshold marginal-threshold 1 down-threshold 2
no protocol vrrp
no protocol vrrp-extended
interface Ve 123
shutdown
!
!
interface Management 1/0
no ip address dhcp
ip address 10.17.10.21/20
ip gateway-address 10.17.0.1
no ipv6 address autoconfig
no ipv6 address dhcp
!
interface TenGigabitEthernet 1/0/1
description LC 1/0/1-23
fabric isl enable
fabric trunk enable
no shutdown
!
interface TenGigabitEthernet 1/0/2
description LC 1/0/1-23
fabric isl enable
fabric trunk enable
no shutdown
!
interface TenGigabitEthernet 1/0/3
mtu 9216
description LC 1/0/1-23
fabric isl enable
fabric trunk enable
See Also