Track – Brocade Network OS Command Reference v4.1.0 User Manual
Page 1363
Network OS Command Reference
1325
53-1003115-01
track
2
track
Specifies a VRRP interface to track.
Synopsis
track {fortygigabitethernet rbridge-id/slot/port | gigabitethernet rbridge-id/slot/port |
port-channel number | tengigabitethernet rbridge-id/slot/port} [priority range]
no track {fortygigabitethernet rbridge-id/slot/port | gigabitethernet rbridge-id/slot/port |
port-channel number | tengigabitethernet rbridge-id/slot/port} [priority range]
Operands
fortygigabitethernet rbridge-id/slot/port
Specifies a valid 40-gigabit Ethernet interface.
rbridge-id
Specifies the RBridge ID.
slot
Specifies a valid slot number.
port
Specifies a valid port number.
gigabitethernet
Specifies a valid 1-gigabit Ethernet interface
rbridge-id
Specifies the RBridge ID.
slot
Specifies a valid slot number.
port
Specifies a valid port number.
port-channel number Specifies the port-channel number. Valid values range from 1
through 6144.
tengigabitethernet
Specifies a valid 10-gigabit Ethernet interface.
rbridge-id
Specifies the RBridge ID.
slot
Specifies a valid slot number.
port
Specifies a valid port number.
priority range
The track priority is a number from 1 through 254, and is used when the
tracked interface up or down event is detected. For VRRP, if the tracked
interface becomes disabled, the current router priority is reduced to the
track-port priority, (For VRRP only, interface tracking does not have any
effect on an owner router; the owner priority can not be changed from 255.)
For VRRP-E, if the tracked interface becomes disabled, the current router
priority is reduced by the track-port priority.
Defaults
Priority range is 2.
Command Modes
Virtual-router-group configuration mode
Description
Use this command to specify a VRRP interface to track.
Usage Guidelines
This command can be used for VRRP or VRRP-E.
For VRRP, the tracked interface can be any 10-gigabit Ethernet, 40-gigabit Ethernet, 1-gigabit
Ethernet, or port-channel interface other than the one on which this command is issued.
The maximum number of interfaces you can track per virtual router is 16.
Enter no track with the specified interface to remove the tracked port configuration.