beautypg.com

Vcs (standalone mode) – Brocade Network OS Command Reference v4.1.0 User Manual

Page 1385

background image

Network OS Command Reference

1347

53-1003115-01

vcs (standalone mode)

2

vcs (standalone mode)

Configures Brocade VCS Fabric technology parameters and can enable one of the two types of
Brocade VCS fabric modes: fabric cluster mode or logical chassis cluster mode.

NOTE

Platforms that allow standalone mode are the Brocade VDS 6710-54, 6720, and 6730.

Synopsis

vcs {[rbridge-id rbridge-id] [vcsId ID] [enable]}

vcs {[rbridge-id rbridge-id] [vcsId ID] [logical-chassis enable]}

no vcs enable

no logical-chassis enable

Operands

rbridge-id rbridge-id Sets the RBridge ID for the switch. This parameter cannot be configured in
non-VCS mode unless the enabling operation is performed at the same time.

vcsId ID

Sets the VCS ID. This parameter cannot be configured in standalone mode
unless the enabling operation is performed at the same time.

enable

Enables Brocade VCS fabric cluster mode.

logical-chassis enable

Enables Brocade VCS logical chassis cluster mode.

Defaults

None

Command Modes

Privileged EXEC mode

Description

Use this command to configure the Brocade VCS Fabric parameters (VCS ID and the switch
RBridge ID) and to enable either of the two types of Brocade VCS fabric modes: fabric cluster mode
or logical chassis cluster mode. You can set the Brocade VCS Fabric parameters and enable one of
the VCS modes at the same time, or you can enable one of the VCS modes and then perform the
ID assignments separately.

Usage Guidelines

Each time you change the Brocade VCS Fabric configuration, the switch resets to the default
configuration and reboots automatically. Make sure to save the configuration before you issue any
of the commands shown in the "Synopsis" section above.

You can use the no form of this command as follows:

To transition a switch from either fabric cluster mode or logical chassis cluster mode back to
standalone mode, run the command: no vcs enable

To transition a switch from logical chassis cluster mode back to fabric cluster mode, run the
command: no logical-chassis enable

Examples

Thefollowing provides command examples of enabling Brocade VCS logical chassis cluster mode: