Firmware recover – Brocade Network OS Command Reference v4.1.0 User Manual
Page 346
308
Network OS Command Reference
53-1003115-01
firmware recover
2
firmware recover
Recovers the previous firmware version on the switch nodes if a firmware upgrade was
unsuccessful.
Synopsis
firmware recover [rbridge-id {rbridge-id_1-rbridge-id_3, rbridge-id_5 | all}]
Operands
rbridge-id
Enables RBridge ID mode to support Virtual Cluster Switching (VCS) on
individual nodes.
rbridge-id
Specifies a unique identifier for a node. Values can be a range of nodes or
individual nodes and are separated by a comma.
all
Specifies all identifiers for a node. The command applies to all of the
nodes. The command applies to all of the nodes.
Defaults
None
Command Modes
Privileged EXEC mode
Description
Allows you to undo the operation that was performed using the firmware download “noactivate”
option.
If you invoke a noactivate firmware download, the firmware is loaded to the secondary node
without swapping partitions. If firmware recover is executed, it will perform a forceful commit in
that node. This CLI does not reboot the node.
Usage Guidelines
The rbridge-id operand is supported in VCS mode only.
Examples
To recover firmware on switch nodes 1, 2, 3, and 5:
switch# firmware recover rbridge-id rid1-rid3,rid5
To perform a firmware recovery on all switch nodes:
switch# firmware recover rbridge-id all
See Also
firmware activate, show version, show firmwaredownloadstatus