Show running-config cee-map – Brocade Network OS Command Reference v4.1.0 User Manual
Page 1039
Network OS Command Reference
1001
53-1003115-01
show running-config cee-map
2
show running-config cee-map
Displays the Converged Enhanced Ethernet (CEE) map.
Synopsis
show running-config cee-map [precedence | priority-group-table [pgid]| priority-table | remap
{fabric-priority | lossless-priority}]
Operands
precedence
Displays only the precedence of the default CEE map.
priority-group-table
Without a specified priority group ID, displays the priority group table for
each priority group ID.
pgid
Specifies one priority group ID.
priority-table
Displays the configured priority table map.
remap fabric-priority Displays the fabric priority for the Brocade VCS Fabric QoS.
remap lossless-priority Displays the lossless priority for the Brocade VCS Fabric QoS.
Defaults
None
Command Modes
Privileged EXEC mode
Description
Use this command to display properties of the configured CEE map. Without parameters, the
command displays the precedence of the default CEE map, priority group table for each priority
group ID, the configured priority table map, and the fabric priority and lossless priority for the
Brocade VCS Fabric QoS.
Usage Guidelines
None
Examples
To display the CEE map:
switch(config)# show running-config cee-map
cee-map default
precedence 1
priority-group-table 1 weight 40 pfc on
priority-group-table 15.0 pfc off
priority-group-table 15.1 pfc off
priority-group-table 15.2 pfc off
priority-group-table 15.3 pfc off
priority-group-table 15.4 pfc off
priority-group-table 15.5 pfc off
priority-group-table 15.6 pfc off
priority-group-table 15.7 pfc off
priority-group-table 2 weight 60 pfc off
priority-table 2 2 2 1 2 2 2 15.0
remap fabric-priority priority 0
remap lossless-prioirty priority 0
!
See Also
priority-group-table, remap fabric-priority, remap lossless-priority