beautypg.com

Show diag post results – Brocade Network OS Command Reference v4.1.0 User Manual

Page 772

background image

734

Network OS Command Reference

53-1003115-01

show diag post results

2

show diag post results

Displays either the brief results or detailed information of the power-on self-test (POST) executed
on the switch.

Synopsis

show diag post results {brief | detailed} [rbridge-id rbridge-id] [slot slot-id]

Operands

brief | detailed

Specifies whether the POST passed or failed (brief) or displays detailed
status with the register dump when a POST fails (detailed).

rbridge-id

Specifies the RBridge ID of the switch.

slot slot_id

Specifies the slot ID. This is mandatory for slot-based systems only.

Defaults

None

Command Modes

Privileged EXEC mode

Description

Use this command to display either the brief results or details of the last diagnostic POST that was
executed.

Usage Guidelines

None

Examples

To display brief POST results (whether the POST passed or failed):

switch# show diag post results brief slot L4

POST1:Slot L4 turboramtest PASSED (exit_status 0).

POST1:Slot L4 Script PASSED with exit_status of 0 Thu Jan 1 00:04:36 GMT 1970 took

(0:0:47)

POST2:Slot L4 portloopbacktest PASSED (exit_status 0).

POST2:Slot L4 prbstest PASSED (exit_status 0).

POST2:Slot L4 Script PASSED with exit_status of 0 Thu Jan 1 00:05:52 GMT 1970 took

(0:1:15)

rbridgeId 1

switch# show diag post results detailed slot S1

POST1:Slot S1 Started running Thu Jan 1 00:02:46 GMT 1970

POST1:Slot S1 Running diagclearerror

POST1:Slot S1 Running diagsetup

POST1:Slot S1 Test #1 - Running turboramtest

Running turboramtest...

:

<..cut..>

:

POST1:Slot S1 ********** Slot S1 POST Summary **********

POST1:Slot S1 Completed 1 Diagnostic test:

POST1:Slot S1 Script PASSED with exit_status of 0 Thu Jan 1 00:02:53 GMT 1970 took

(0:0:7)

POST2:Slot S1 Started running Thu Jan 1 00:02:58 GMT 1970

POST2:Slot S1 Running diagclearerror

POST2:Slot S1 Test #1 - Running portloopbacktest

Running portloopbacktest...

:

<..cut..>

:

POST2: ********** Slot S1 POST Summary **********

POST2:Slot S1 Completed 2 Diagnostic test:

POST2:Slot S1 Script PASSED with exit_status of 0 Thu Jan 1 00:03:35 GMT 1970 took

(0:0:37)