beautypg.com

Sflow polling-interval (global version) – Brocade Network OS Command Reference v4.1.0 User Manual

Page 715

background image

Network OS Command Reference

677

53-1003115-01

sflow polling-interval (global version)

2

sflow polling-interval (global version)

Configures the polling interval globally.

Synopsis

sflow polling-interval interval_value

no sflow polling-interval interval_value

Operands

interval_value

Specifies a value in seconds to set the polling interval. Valid values range
from 1 through 65535 seconds.

Defaults The default is 20.

Command Modes

Global configuration mode

Description

Use this command to configure the polling interval globally. The interval is the maximum number
of seconds between successive samples of counters to be sent to the collector.

Usage Guidelines

Enter no sflow polling interval interval_value to return to the default value.

Examples

To set the polling interval to 135 seconds:

switch(config)# sflow polling-interval 135

See Also

sflow polling-interval (interface version)