Network OS Command Reference

421

53-1003115-01

linecard

2

linecard

Configures an interface module (line card).

Synopsis

linecard slot_number linecard_type

no linecard slot_number

Operands

slot_number

Specifies the slot number to be configured. Interface module slots are
slots 1 through 4 on a Brocade VDX 8770-4 and slots 1 through 8 on a
Brocade VDX 8770-8.

linecard_type

Specifies the type of interface module. Supported types include the
following:

LC12x40G12-port 40 GbE interface module

LC48x1G48-port 1 GbE interface module

LC48x10G48-port 10 GbE interface module

LC72x1G72-port 1 GbE interface module (Not supported)

Defaults

None

Command Modes

Global configuration mode

RBridge ID configuration mode

Description

Use this command to configure the specified slot for an interface module of a given type.

The command is executed in the context of the given RBridge. You must first enter the rbridge-id
context for the specific interface module. Once you are in the rbridge-id context, enter
linecard slot_number linecard_type to configure the slot.

Usage Guidelines

If you replace a given interface module with another one of a different type, you must remove the
configuration and then reconfigure the slot.

The interface module must be powered off before you can remove the slot configuration.

The LC72x1G type displayed under “possible completion” is not supported.

CAUTION

Enter no linecard to remove the slot configuration.When hot-swapping line cards of different
types, copy the running-config file to the startup-config file before rebooting. This ensures that
the desired changes are persistent in case there are any hardware or software incompatibilities.

Examples

To configure a slot for an interface module on a switch in VCS mode and to verify the configuration:

switch# configure

Entering configuration mode terminal

switch(config)# rbridge-id 1

switch(config-rbridge-id-1)# linecard 1 ?

Possible completions:

LC12x40G

12X40G linecard

LC48x1G

48X1G linecard

LC48x10G

48X10G linecard