beautypg.com

Brocade Network OS Command Reference v4.1.0 User Manual

Page 261

background image

Network OS Command Reference

223

53-1003115-01

diag portloopbacktest

2

Usage Guidelines

During abnormal termination, the system might be in unusable state. Perform reload to reboot the
chassis or switch to recover.

In slot-based systems, the blade under test undergoes a reset or a reinitialization sequence as
part of cleanup.

The rbridge-id is an optional parameter. If the rbridge-id is not specified, the test is assigned to the
local RBridge ID.

CAUTION

This is a disruptive command. You must disable the chassis and switch before running the test. In
addition, you must reload or fastboot the switch or chassis after the test has completed running.

Examples

In slot-based switches:

switch# diag portloopbacktest slot S1

% Info: This test should be run to completion. Please do not abort while it is

executing.

Running portloopbacktest...

<..cut..>

portLoopbackTest on ports 0-143 PASSED

portLoopbackTest on slot S1 PASSED

% Info: Resetting the blade. Please wait till it gets initialized...

In fixed-configuration switches:

switch# diag portloopbacktest

% Info: This test should be run to completion. Please do not abort while it is

executing.

Running portloopbacktest ..............

PASSED.

See Also

diag portledtest, diag post enable, diag turboramtest