Brocade Network OS Command Reference v4.1.0 User Manual
Page 332

294
Network OS Command Reference
53-1003115-01
firmware download
2
(output truncated)
To download firmware to a local node:
switch# firmware download protocol ftp host 10.1.2.30 user fvt password
pray4green path /dist file release.plist
This command will download the firmware to the local node. You will need to run
firmware activate to activate the firmware after this command completes.
Do you want to continue? [y/n]: y
2010/01/29-23:48:35, [HAM-1004], 226, switchid 1, CHASSIS | VCS, INFO,
Brocade_switch,
Firmwaredownload has started on the switch.
To download firmware using the default-config option with VCS mode 1, VCS ID 7, and RBridge 10,
use the following command:
sw0# firmware download default-config ftp host 10.20.1.3 user fvt password
pray4green directory dist file release.plist vcs-mode 1 vcs-id 7 rbridge-id 10
Performing system sanity check...
This command will set the configuration to default and set the following
parameters: vcs-mode, vcs-id and rbridge-id.
This command will cause Cold reboot on both MMs at the same time and will require
that existing telnet, secure telnet or SSH sessions be restarted.
Do you want to continue? [y/n]: y
host 10.20.1.3 user fvt password pray4green directory dist file release.plist
Performing system sanity check...
This command will set the configuration to default and set the following
parameters: vcs-mode, vcs-id and rbridge-id.
This command will cause Cold reboot on both MMs at the same time and will require
that existing telnet, secure telnet or SSH sessions be restarted.
Do you want to continue? [y/n]: y
See Also
firmware commit, firmware restore, show firmwaredownloadstatus, show version