beautypg.com

Threshold-monitor sfp – Brocade Network OS Command Reference v4.1.0 User Manual

Page 1356

background image

1318

Network OS Command Reference

53-1003115-01

threshold-monitor sfp

2

threshold-monitor sfp

Configures monitoring of SFP parameters.

Synopsis

threshold-monitor sfp {[apply policy_name | pause | policy policy_name] type SFP_type area
parameters
alert

[above [highthresh-action [[all | lowthresh-action] | email | none | raslog] |

lowthresh-action [all | email none | raslog] |

below [highthresh-action [all | email | none raslog] | lowthresh-action [all | email |

none | raslog]] |

threshold

[buffer | high-threshold | low-threshold | timebase [day | hour | minute | none]]]}

no threshold-monitor sfp

Operands

apply

Applies a custom policy that has been created by the policy operand.

policy_name

Name of a custom policy configuration created by the policy operand.

pause

Pause monitoring.

policy

Specifies a policy name for monitoring by means of custom settings, rather
than default settings. A policy name is required before additional
configurations can be made. This operation is not supported from a
secondary node.

policy_name

Name of a custom policy configuration that can be saved and applied by
means of the apply operand.

type

Specifies the SFP type. Possible completions are as follows:

1GLR

— SFP Type 1GLR

1GSR

— SFP Type 1GSR

10GLR

— SFP Type 10GLR

10GSR

— SFP Type 10GSR

10GUSR

— SFP Type 10GUSR

100GSR

—SFP Type 100GSR

QSFP

— SFP type QSFP

area

Specifies one of the following SFP parameters to be monitored. See
Defaults, below.

Current

Measures the current supplied to the SFP transceiver.

RXP

Measures the incoming laser power, in microWatts (

µW)

.

TXP

Measures the outgoing laser power, in

µW)

.

Temperature

Measures the temperature of the SFP, in degrees Celsius.

Voltage

Measures the voltage supplied to the SFP.

alert

Specifies whether an alert is sent when a threshold value is either above or
below a threshold trigger.