system-monitor

2

system-monitor

Manages the monitoring of FRUs and sets a variety of alerts when thresholds are exceeded.

Synopsis

system-monitor
{LineCard [alert [action [all | email | none | raslog]] | state [all | faulty | inserted | none | on |

removed]] | threshold [down-threshold | marginal-threshold]] |

MM [threshold [down-threshold | marginal-threshold]] |
cid-card [alert [action | state [all | faulty | inserted | none | on | removed]] | threshold

[down-threshold | marginal-threshold]] |

compact-flash [threshold [down-threshold | marginal-threshold]] |
fan [alert [action | state [all | faulty | inserted | none | on | removed]] | threshold

[down-threshold | marginal-threshold]] |

power [alert [action | state [all | faulty | inserted | none | on | removed]] | threshold

[down-threshold | marginal-threshold]]

sfp [alert [action state]]
temp [threshold [down-threshold | marginal-threshold]]}

no system-monitor

Operands

LineCard

Specifies alerts and thresholds for line cards.

MM

Specifies thresholds for management modules.

cid-card

Specifies alerts and thresholds for the chassis ID card.

compact-flash

Specifies thresholds for the compact flash device.

fan

Specifies alerts and thresholds for the fans.

power

Specifies alerts and thresholds for the power supplys.

sfp

Specifies alerts for the small form-factor pluggable devices.

temp

Specifies thresholds for the temperature sensors.

alert

Specifies whether an alert is sent when a threshold value is either above or
below a threshold trigger.

action

Specifies the response type.

all

Specifies that e-mail and RASLog messaging are used.

email

Specifies that an e-mail message is sent.

none

Specifies that no message is sent.

raslog

Specifies RASLog messaging.

state

Specifies the hardware state to be monitored.

all

Specifies that all hardware states are monitored.

faulty

Specifies that hardware is monitored for faults.

inserted

Specifies that the insertion state of hardware is monitored.

none

Specifies that no hardware states are monitored.

on

Specifies that the hardware on/off state is monitored.

removed

Specifies that the removal of hardware is monitored.