switchport mode

2

switchport mode

Sets the mode of the interface.

Synopsis

switchport mode {access | trunk}

Operands

access

Sets the Layer 2 interface as access.

trunk

Sets the Layer 2 interface as trunk.

Defaults

None

Command Modes

Interface subtype configuration mode

Description

Use this command to set the mode of the Layer 2 interface. Access mode assigns the port to a
VLAN (refer to the Usage Guidelines). Trunk mode makes the port linkable to other switches and
routers.

Usage Guidelines

You must configure the same native VLAN on both ends of an 802.1 or classified VLAN trunk link.
Failure to do so can cause bridging loops and VLAN leaks.

On the Brocade VDX family of switches, VLANs are treated as interfaces from a configuration point
of view. By default, all the DCB ports are assigned to VLAN 1 (VLAN ID equals 1). Valid VLAN IDs
are as follows:

On Brocade VDX 8770 switches: 1 through 4086 for 802.1Q VLANs (VLAN IDs 4087
through 4095 are reserved on these switches), and 4096 through 8191 for service or
transport VFs in a Virtual Fabrics context.

On all other Brocade VDX switches: 1 through 3962 for 802.1Q VLANs (VLAN IDs 3963
through 4095 are reserved on these switches), and 4096 through 8191 for service or
transport VFs in a Virtual Fabrics context.

Examples

To set the mode of a specific 10-gigabit Ethernet interface to access:

switch(config)# interface tengigabitethernet 178/0/9

switch(conf-if-te-178/0/9)# switchport mode access

To set the mode of a specific port-channel interface to trunk:

switch(config)# interface port-channel 44

switch(config-port-channel-44)# switchport mode trunk

See Also