threshold-monitor cpu
Configures monitoring of CPU usage of the system and alerts the user when configured thresholds
are exceeded.
Synopsis
threshold-monitor cpu {[actions [none | raslog [{limit limit_when_reached | poll polling_interval |
retry number_of_retries]]}
no threshold-monitor cpu
Operands
actions
Specifies the action to be taken when a threshold is exceeded.
none
No action is taken.
raslog
Specifies RASLog messaging.
limit
Specifies the baseline CPU usage limit as a percentage of available
resources.
limit_when_reached
When the limit set by this parameter is exceeded, a RASLog WARNING
message is sent. When the usage returns below the limit, a RASLog INFO
message is sent. Valid values range from 0 through 80 percent. The default
is 70 percent.
poll
Specifies the polling interval in seconds.
polling_interval
The range is from 0 through 3600. The default is 120
retry
Specifies the number of polling retries before desired action is taken.
number_of_retries
Range is from 1 through 100. The default is 3.
Defaults
Refer to the Operands for specific defaults.
Command Modes
RBridge ID configuration mode
Description
Use this command to monitor CPU usage and send a RASLog WARNING message when configured
thresholds are exceeded.
Usage Guidelines
None
Examples
switch(config-rbridge-id-154)# threshold-monitor cpu actions rasloglimit 50
poll10