Clear edge-loop-detection – Brocade Network OS Command Reference v4.1.0 User Manual
Page 146

108
Network OS Command Reference
53-1003115-01
clear edge-loop-detection
2
clear edge-loop-detection
Re-enables all ports disabled by ELD and clears all ELD statistics.
Synopsis
clear edge-loop-detection [rbridge-id rbridge-id]
clear edge-loop-detection interface {fortygigabitethernet {rbridge-id/slot/port} |
gigabitethernet {rbridge-id/slot/port} | tengigabitethernet {rbridge-id/slot/port} | port-channel
num}
Operands
rbridge-id
A unique identifier for the switch. Values are from 1 through 239.
fortygigabitethernet rbridge-id/slot/port
Specifies a valid 1-gigabit Ethernet interface.
rbridge-id
Specifies the RBridge ID. This is not valid in standalone mode.
slot
Specifies a valid slot number.
port
Specifies a valid port number.
gigabitethernet rbridge-id/slot/port
Specifies a valid 1-gigabit Ethernet interface.
rbridge-id
Specifies the RBridge ID. This is not valid in standalone mode.
slot
Specifies a valid slot number.
port
Specifies a valid port number.
tengigabitethernet rbridge-id/slot/port
Specifies a valid 10-gigabit Ethernet interface.
rbridge-id
Specifies the RBridge ID. This is not valid in standalone mode.
slot
Specifies a valid slot number.
port
Specifies a valid port number.
port-channel number
Specifies the interface is a port-channel. The number of available channels
range from 1 through 63 for standalone mode, and from 1 through 6144
for Brocade VCS Fabric mode. However, the channel can be assigned any
number from 1 through 6144.
None
Defaults
None
Command Modes
ELD configuration mode
Description
Use this command to re-enable all ports shut down by ELD on the Brocade VCS cluster and to clear
all ELD statistics. This operation is typically performed after correcting a configuration error that
caused ELD to disable ports.
Usage Guidelines
This command applies to Brocade VCS Fabric mode only.
This functionality detects Layer 2 loops only.
If the rbridge-id is specified, it clears edge-loop-detection from the specific node. Otherwise, it
clears edge-loop-detection from all nodes in the VCS cluster.