108

Network OS Command Reference

53-1003115-01

clear edge-loop-detection

2

clear edge-loop-detection

Re-enables all ports disabled by ELD and clears all ELD statistics.

Synopsis

clear edge-loop-detection [rbridge-id rbridge-id]

clear edge-loop-detection interface {fortygigabitethernet {rbridge-id/slot/port} |
gigabitethernet {rbridge-id/slot/port} | tengigabitethernet {rbridge-id/slot/port} | port-channel
num}

Operands

rbridge-id

A unique identifier for the switch. Values are from 1 through 239.

fortygigabitethernet rbridge-id/slot/port

Specifies a valid 1-gigabit Ethernet interface.

rbridge-id

Specifies the RBridge ID. This is not valid in standalone mode.

slot

Specifies a valid slot number.

port

Specifies a valid port number.

gigabitethernet rbridge-id/slot/port

Specifies a valid 1-gigabit Ethernet interface.

rbridge-id

Specifies the RBridge ID. This is not valid in standalone mode.

slot

Specifies a valid slot number.

port

Specifies a valid port number.

tengigabitethernet rbridge-id/slot/port

Specifies a valid 10-gigabit Ethernet interface.

rbridge-id

Specifies the RBridge ID. This is not valid in standalone mode.

slot

Specifies a valid slot number.

port

Specifies a valid port number.

port-channel number

Specifies the interface is a port-channel. The number of available channels
range from 1 through 63 for standalone mode, and from 1 through 6144
for Brocade VCS Fabric mode. However, the channel can be assigned any
number from 1 through 6144.

None

Defaults

None

Command Modes

ELD configuration mode

Description

Use this command to re-enable all ports shut down by ELD on the Brocade VCS cluster and to clear
all ELD statistics. This operation is typically performed after correcting a configuration error that
caused ELD to disable ports.

Usage Guidelines

This command applies to Brocade VCS Fabric mode only.

This functionality detects Layer 2 loops only.

If the rbridge-id is specified, it clears edge-loop-detection from the specific node. Otherwise, it
clears edge-loop-detection from all nodes in the VCS cluster.