C00496 | encoder evaluation method digin12, C00497 | filter time constant, C00497 – Lenze 8400 TopLine User Manual
Page 999: C00497/2, C00497/1, C00497/4, C00497/3, C00496, Ction in, 17 parameter reference
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
999
17
Parameter reference
17.2
Parameter list | C00496
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00496
C00497
Parameter | Name:
C00496 | Encoder evaluation method DigIn12
Data type: UNSIGNED_8
Index: 24079
d
= 5E0F
h
Selection list
(Lenze setting printed in bold)
Info
0 High-resolution encoders
High-precision procedure for high-resolution encoders
(>=512 increments)
1 Low-resolution encoder (StateLine)
High-precision procedure for low-resolution encoders
(<=128 increments)
2 Comb. encoder procedure
Combination of the first two procedures as a function of
the speed (recommended procedure)
3 Edge-counting procedure
Simple edge counting procedure with adjustable
scanning time (
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00497 | Filter time constant
Data type: UNSIGNED_16
Index: 24078
d
= 5E0E
h
Setting range
(min. value | unit | max. value)
0.0
ms
500.0
Subcodes
Lenze setting
Info
C00497/1
1.0 ms
FreqIn12: Encoder filter time
C00497/2
1.0 ms
FreqIn67: Encoder filter time
C00497/3
1.0 ms
: Encoder filter time
C00497/4
2.0 ms
: Encoder filter time
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10