C00510 | pw protection config mci, C00510/1, 17 parameter reference – Lenze 8400 TopLine User Manual
Page 1006
17
Parameter reference
17.2
Parameter list | C00510
1006
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00510
C00516
Parameter | Name:
C00510 | PW protection config MCI
Data type: UNSIGNED_16
Index: 24065
d
= 5E01
h
From version 15.00.00
Configuration of the password protection for parameter access via fieldbus interface ("MCI")
Individual password protection for single communication channels
Setting range
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Info
Bit 0
Reserved
Bit 1 Parameter write protection
The fieldbus interface (MCI) cannot be used to write into
write/read parameters.
Bit 2 Parameter read protection
The fieldbus interface (MCI) cannot be used to read
write/read parameters.
Bit 3
Reserved
Bit 4
Reserved
Bit 5
Reserved
Bit 6
Reserved
Bit 7
Reserved
Bit 8
Reserved
Bit 9
Reserved
Bit 10
Reserved
Bit 11
Reserved
Bit 12
Reserved
Bit 13
Reserved
Bit 14
Reserved
Bit 15
Reserved
Subcodes
Lenze setting
Info
C00510/1
0x0006
PW protection config. MCI
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00516 | Checksums
Data type: UNSIGNED_32
Index: 24059
d
= 5DFB
h
This code is for device-internal use only and must not be written to by the user!