C00603 | resp. to feedback, C00604 | resp. to device overload (ixt), C00604 – Lenze 8400 TopLine User Manual
Page 1021: C00603/1, C00603/2, C00603 2, C00603 1, As a response for, Of an error response in, C00603/4
![background image](/manuals/566308/1021/background.png)
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
1021
17
Parameter reference
17.2
Parameter list | C00603
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00603
C00604
Parameter | Name:
C00603 | Resp. to feedback
Data type: UNSIGNED_8
Index: 23972
d
= 5DA4
h
Response of different monitoring modes for the encoder/feedback system
Selection list
0 No Reaction
1 Fault
2 Trouble
3 TroubleQuickStop
4 WarningLocked
5 Warning
6 Information
Subcodes
Lenze setting
Info
C00603/1
1: Fault
Resp. to MultiEncoder open circuit
C00603/2
1: Fault
Resp. to resolver open circuit
C00603/3
0: No Reaction
Up to and including version 02.xx.xx:
Resp. to encoder communication error
From version 12.00.00:
Resp. to encoder angular drift monitoring
C00603/4
1: Fault
Up to and including version 02.xx.xx:
Resp. to encoder angular drift monitoring
From version 12.00.00:
Resp. to encoder communication error
C00603/5
6: Information
Resp. to Hiperface status
•
From version 14.00.00
C00603/6
6: Information
Resp. to invalid Hiperface position
•
From version 14.00.00
C00603/7
6: Information
Resp. to SinCos inaccuracy
•
From version 14.00.00
C00603/8
1: Fault
Resp. to Hiperface sin/cos deviation
•
From version 15.00.00
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00604 | Resp. to device overload (Ixt)
Data type: UNSIGNED_8
Index: 23971
d
= 5DA3
h
Response if the adjustable device utilisation threshold (
• The current device utilisation is displayed in
Selection list
(Lenze setting printed in bold)
0 No Reaction
1 Fault
5 Warning
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1