C01206 | mck: mounting direction, C01210 | mck: current positions, C01206/1 – Lenze 8400 TopLine User Manual
Page 1177: C01206/2, C01210/3, C01210/5, C01210/7, C01210/9, C01210/1, C01210/2
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
1177
17
Parameter reference
17.2
Parameter list | C01206
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01206
C01210
Parameter | Name:
C01206 | MCK: Mounting direction
Data type: UNSIGNED_8
Index: 23369
d
= 5B49
h
Inversion for mirrored motor and encoder mounting
Selection list
0 not inverted
1 inverted
Subcodes
Lenze setting
Info
C01206/1
0: Not inverted
Motor mounting direction
• Setting for motor mounting turned by 180°.
C01206/2
0: Not inverted
Position encoder mounting direction
• Setting for position encoder system mounting turned
by 180°.
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01210 | MCK: Current positions
Data type: INTEGER_32
Index: 23365
d
= 5B45
h
Display of current position data of the Motion Control Kernel
Display range
(min. value | unit | max. value)
-214748.3647
units
214748.3647
Subcodes
Info
C01210/1
MCK: Feed
• Display of the current feed for positioning profiles as
a relative distance.
C01210/2
MCK: Set position
• Display of the current setpoint position calculated by
the MCK.
C01210/3
MCK: Actual position
• Display of the current actual position calculated by an
optional encoder system.
C01210/4
MCK: Following error
• Display of the current following error as a difference
between setpoint position and actual position.
C01210/5
MCK: Positioning accuracy
• Display of the current positioning accuracy referred to
the actual number of increments of the position
encoder.
C01210/6
MCK: Target position
C01210/7
MCK: Set position modulo
C01210/8
MCK: Actual position modulo
•
From version 12.00.00
C01210/9
MCK: Dist. ref. mark and Ref-TP
•
From version 14.00.00
• Display of the distance between pre-stop mark/limit
switch and TP/MP while homing.
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10000