19
Function library
19.1
Function blocks
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
0.000
s
999.900 Deceleration time T
if
for the
additional setpoint
• Lenze setting: 0.000 s
0.00
%
100.00 Hysteresis window for zero detection
of speed output setpoint (output
bRfgIEqO)
• Lenze setting: 0.50 %
0.00
%
199.99 Maximum limit values for the speed
blocking zones
• Selection of the maximum limit
values for the blocking zones in
which the speed must not be
constant.
• Lenze setting: 0.00 %
0.00
%
199.99 Minimum limit values for the speed
blocking zones
• Selection of the minimum limit
values for the blocking zones in
which the speed must not be
constant.
• Lenze setting: 0.00 %
Status (bit-coded)
• Bits that are not listed are
reserved for future extensions.
Bit 0 No blocking zone active
Bit 1 Blocking zone 1 active
Bit 2 Blocking zone 2 active
Bit 3 Blocking zone 3 active
Bit 4 Jog in blocking zone
Bit 5 MaxLimit active
Bit 6 MinLimit active
-199.99
%
199.99 nMaxLimit
• Maximum speed setpoint for
speed setpoint limitation
• Lenze setting: 199.99 %
-199.99
%
199.99 nMinLimit
• Minimum speed setpoint for
speed setpoint limitation
• Lenze setting: -199.99 %
-199.99
%
199.99 Blocking zone output
• Display of the speed setpoint after
being processed by blocking zone
function.
-199.99
%
199.99 Ramp smoothing output
• Display of the speed setpoint after
being processed by PT1 filter
function.
-199.99
%
199.99 Additional value output
• Display of the additional speed
setpoint after being processed by
ramp generator.
-199.99
%
199.99 Output nNOut_a
• Display of the generated main
speed setpoint at the nNOut_a
output.
Parameter
Possible settings
Info