6 VFCplus: V/f linear
This control type is used for the speed control of an
asynchronous motor via a linear V/f characteristic and is
the simplest control type.
• For setting the V/f characteristic, only the rated
frequency (
) and the rated voltage (
) of
the motor have to be entered.
7 VFCplus: V/f linear + encoder
This control type is used for speed control of an
asynchronous motor via a linear V/f characteristic.
• The control type requires a speed feedback via an
encoder mounted to the motor!
• For setting the V/f characteristic, only the rated
frequency (
) and the rated voltage (
) of
the motor have to be entered.
8 VFCplus: V/f quadr
This control type is used for speed control of an
asynchronous motor via a square-law V/f characteristic.
• For setting the V/f characteristic, only the rated
frequency (
) and the rated voltage (
) of
the motor have to be entered.
9 VFCplus: V/f quadr + encoder
This control type is used for speed control of an
asynchronous motor via a square-law V/f characteristic.
• The control type requires a speed feedback via an
encoder mounted to the motor!
• For setting the V/f characteristic, only the rated
frequency (
) and the rated voltage (
) of
the motor have to be entered.
10 VFCplus: V/f definable
This type of control is used for the speed control of an
asynchronous motor via a user-definable characteristic
with several interpolation points.
• For setting the V/f characteristic, only the rated
frequency (
) and the rated voltage (
) of
the motor have to be entered.
11 VFCplusEco: V/f energy-saving
This control type is used for energy-saving speed control
of an asynchronous motor via a linear V/f characteristic.
• For setting the V/f characteristic, only the rated
frequency (
) and the rated voltage (
) of
the motor have to be entered.
• Predestinated application areas of this control type
are materials handling technology and pump and fan
systems.
V/f characteristic control, energy-saving
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00006 | Motor control
Data type: UNSIGNED_8
Index: 24569
d
= 5FF9
h