C00672 | l_offsetgainp_3: gain, C00673 | l_offsetgainphip 1-2: offset, C00674 | l_offsetgainphip 1-2: gain – Lenze 8400 TopLine User Manual
Page 1044: C00677 | l_gainoffsetp 1-3: parameter, C00672, 17 parameter reference
17
Parameter reference
17.2
Parameter list | C00672
1044
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00672
C00673
C00674
C00677
Parameter | Name:
C00672 | L_OffsetGainP_3: Gain
Data type: INTEGER_32
Index: 23903
d
= 5D5F
h
FB: Gain as multiplier of the input signal + offset
Setting range
(min. value | unit | max. value)
Lenze setting
-100.0000
100.0000 1.0000
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10000
Parameter | Name:
C00673 | L_OffsetGainPhiP 1-2: Offset
Data type: INTEGER_32
Index: 23902
d
= 5D5E
h
Angular offset (is added to the angular input signal)
Setting range
(min. value | unit | max. value)
-2147483647
Incr.
2147483647
Subcodes
Lenze setting
Info
C00673/1
0 incr.
: Offset
C00673/2
0 incr.
: Offset
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00674 | L_OffsetGainPhiP 1-2: Gain
Data type: INTEGER_32
Index: 23901
d
= 5D5D
h
Angular gain as multiplier of the input signal + angular offset
Setting range
(min. value | unit | max. value)
-2147483647
2147483647
Subcodes
Lenze setting
Info
C00674/1
65536
: Gain
C00674/2
65536
: Gain
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00677 | L_GainOffsetP 1-3: Parameter
Data type: INTEGER_16
Index: 23898
d
= 5D5A
h
Gain and offset
Setting range
(min. value | unit | max. value)
-199.99
%
199.99
Subcodes
Lenze setting
Info
C00677/1
100.00 %
: Gain
C00677/2
0.00 %
: Offset
C00677/3
100.00 %
: Gain
C00677/4
0.00 %
: Offset
C00677/5
100.00 %
: Gain
C00677/6
0.00 %
: Offset
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100