17 parameter reference – Lenze 8400 TopLine User Manual
Page 1312
17
Parameter reference
17.6
Table of attributes
1312
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Power section ID
Linear value
24482
5FA2
E
1
UNSIGNED_16
1
Motor magnetising current
Linear value
24480
5FA0
E
1
UNSIGNED_16
100
Rated motor torque
Linear value
24478
5F9E
E
1
UNSIGNED_32
100
Rated device current
Linear value
24477
5F9D
E
1
UNSIGNED_16
10
Firmware version
String
24476
5F9C
E
1
VISIBLE_STRING [12]
Firmware version
Linear value
24475
5F9B
A
4
UNSIGNED_8
1
Add. acceleration time x
Linear value
24474
5F9A
A
15
UNSIGNED_32
1000
Add. deceleration time x
Linear value
24472
5F98
A
15
UNSIGNED_32
1000
Quick stop setting
Bit coded
24471
5F97
A
1
UNSIGNED_16
1
Decel. time - quick stop
Linear value
24470
5F96
E
1
UNSIGNED_32
1000
Auto-DCB: Hold time
Linear value
24469
5F95
E
1
UNSIGNED_32
1000
DC braking: Hold time
Linear value
24468
5F94
E
1
UNSIGNED_32
1000
DigInX: Inversion
Bit coded
24461
5F8D
E
1
UNSIGNED_16
1
DI 1/2 & 6/7: Function
Selection list
24460
5F8C
A
2
UNSIGNED_8
1
Status of brake output BD
Selection list
24458
5F8A
E
1
UNSIGNED_8
1
DigOutX: Inversion
Bit coded
24457
5F89
E
1
UNSIGNED_8
1
Setting of motor overload (I²xt)
Linear value
24455
5F87
E
1
INTEGER_16
100
Motor temp. warning threshold
Linear value
24454
5F86
A
2
UNSIGNED_16
1
Initial value motor overload (I²xt)
Linear value
24453
5F85
A
1
UNSIGNED_16
100
Device utilisat. threshold (Ixt)
Linear value
24452
5F84
E
1
INTEGER_16
100
Brake resistance value
Linear value
24446
5F7E
E
1
UNSIGNED_16
10
Rated brake resistor power
Linear value
24445
5F7D
E
1
UNSIGNED_16
1
Thermal capacity - brake resistor
Linear value
24444
5F7C
E
1
UNSIGNED_16
10
Brake resistor utilisation
Linear value
24442
5F7A
E
1
UNSIGNED_16
1
L_NSet_1: Ramp smoothing
Selection list
24441
5F79
E
1
UNSIGNED_8
1
Communication control words
Bit coded
24439
5F77
A
2
UNSIGNED_16
1
Device status
Selection list
24438
5F76
E
1
UNSIGNED_16
1
Internal control signals
Bit coded
24437
5F75
A
3
UNSIGNED_16
1
Auto-start option
Bit coded
24433
5F71
E
1
UNSIGNED_8
1
Thermal switching frequency reduction
Selection list
24431
5F6F
E
1
UNSIGNED_8
1
LS_DriveInterface: Error message config.
Bit coded
24427
5F6B
E
1
UNSIGNED_16
1
Status word
Bit coded
24425
5F69
E
1
UNSIGNED_16
1
Extended status word
Bit coded
24420
5F64
E
1
UNSIGNED_16
1
Cause of controller inhibit
Bit coded
24417
5F61
E
1
UNSIGNED_16
1
Cause of quick stop QSP
Bit coded
24416
5F60
E
1
UNSIGNED_16
1
Status determining error (16-bit)
Linear value
24415
5F5F
A
1
UNSIGNED_16
1
LS_SetError_x: Error number
Linear value
24414
5F5E
A
8
UNSIGNED_16
1
Error number masked
Linear value
24413
5F5D
A
1
UNSIGNED_32
1
Logbook - binary elements
Selection list
24412
5F5C
A
2
UNSIGNED_16
1
Logbook - analog elements
Selection list
24411
5F5B
A
1
UNSIGNED_16
1
Error information
String
24410
5F5A
A
2
VISIBLE_STRING [14]
Error information text
String
24409
5F59
A
6
VISIBLE_STRING [31]
Status determining error
Linear value
24407
5F57
E
1
UNSIGNED_32
1
Logbook setting
Bit coded
24406
5F56
E
1
UNSIGNED_16
1
Current error
Linear value
24405
5F55
E
1
UNSIGNED_32
1
Mains voltage
Selection list
24402
5F52
E
1
UNSIGNED_8
1 CINH
Reduc. brake chopper threshold
Linear value
24401
5F51
E
1
UNSIGNED_8
1
Brake energy management
Selection list
24400
5F50
E
1
UNSIGNED_8
1 CINH
Switching cycles
Linear value
24398
5F4E
A
8
UNSIGNED_32
1
Elapsed-hour meter
Linear value
24397
5F4D
E
1
UNSIGNED_32
1
Code
Name
Type
Index
Data
dec
hex
DS
DA
DT
Factor
CINH
Grayed out = display parameter (read access only)