C01353 | acdrive: setpoint scaling, C01400 | l_sequencer_1: sequence step, C01401 | l_sequencer_1: current step – Lenze 8400 TopLine User Manual
Page 1205: C01353/1, Ac drive attri, C01353/2, 17 parameter reference
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
1205
17
Parameter reference
17.2
Parameter list | C01353
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01353
C01400
C01401
Parameter | Name:
C01353 | ACDrive: Setpoint scaling
Data type: INTEGER_8
Index: 23222
d
= 5AB6
h
From version 13.00.00
Actuating drive speed (AC Drive Profil): Scaling of the speed and torque values
Setting range
(min. value | unit | max. value)
-128
127
Subcodes
Lenze setting
Info
C01353/1
0
ACDrive: Speed scaling
C01353/2
0
ACDrive: Torque scaling
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01400 | L_Sequencer_1: Sequence step
Data type: UNSIGNED_16
Index: 23175
d
= 5A87
h
From version 12.00.00
In the subcodes, the calls of the actions required for the positioning program are stored. In this way, the basic
sequence (with the exception of the branches) is defined.
L_Sequencer_1 (sequence control)
Setting range
(min. value | unit | max. value)
0
10005
Subcodes
Lenze setting
Info
C01400/1
0
: Action in sequence step 1
C01400/...
...
C01400/100
: Action in sequence step 100
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01401 | L_Sequencer_1: Current step
Data type: UNSIGNED_16
Index: 23174
d
= 5A86
h
From version 12.00.00
L_Sequencer_1 (sequence control)
Display range
(min. value | unit | max. value)
0
100
Subcodes
Info
C01401/1
: Current step
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1