8.4.3
Terminal assignment of the control modes
The following comparison provides information about which inputs/outputs of the application block LA_TabPos are interconnected to the
digital and analog input/output terminals of the drive controller in the different control modes.
Control mode (
)
10:
12:
14:
16:
20:
21:
30:
40:
Digital input terminals
X5/RFR
Controller enable / Reset of error message
bFailReset
X5/DI1
-
-
Positive limit switch
bLimitSwitchPos
-
-
-
-
-
X5/DI2
-
-
Negative limit switch
bLimitSwitchNeg
-
-
-
-
-
X5/DI3
Positive limit switch
bLimitSwitchPos
-
-
Manual jog
in positive direction
bManJogPos
-
-
Positive limit switch
bLimitSwitchPos
X5/DI4
Negative limit switch
bLimitSwitchNeg
Positioning profile, array bit (valency 4)
bPosProfileNo_4
Manual jog
in negative direction
bManJogNeg
-
-
Negative limit switch
bLimitSwitchNeg
X5/DI5
Positioning profile, array bit (valency 2)
bPosProfileNo_2
-
-
Home position
bHomeMark
X5/DI6
Positioning profile, array bit (valency 1)
bPosProfileNo_1
-
-
Quick stop
bSetQuickstop
X5/DI7
Start of profile generation
bPosExecute
-
-
Status word - bit 7
LP_CanOut1: bState_B7
Status word - bit 7
LP_MciOut: bState_B7
Analog input terminals
X3/A1U
Main speed setpoint
nMainSetValue_a
10 V ≡ 100 % reference speed (
-
-
Main speed setpoint
nMainSetValue_a
10 V ≡ 100 % reference speed (
)
X3/A1I
X3/A2U
-
-
-
-
-
-
-
-
X3/A2I
-
-
-
-
-
-
-
-
Digital output terminals
X4/DO1
Status "Drive is ready" (bDriveReady)
X4/DO2
Status "Target position (actual value) is in the target window" (bInTarget)
X4/DO3
Status "Home position is known"(bHomePosAvailable)
Status "Maximum current limit" (bImaxActive)
X107/BD1, BD2
Control of the holding brake (bMBrakeReleaseOut)
X101/COM, NO
Status "Error is pending" (bDriveFail)
Analog output terminals
X3/O1U
Actual speed value
nMotorSpeedAct_a
10 V ≡ 100 % reference speed (
)
X3/O1I
X3/O2U
Actual motor current
nMotorCurrent_a
10V ≡ 100% of I
max_mot
X3/O2I