C01407 | l_sequencer_1: psprofil, C01408 | l_sequencer_1: psstep, C01409 | l_sequencer_1: ps_wd_time – Lenze 8400 TopLine User Manual
Page 1208: 17 parameter reference
17
Parameter reference
17.2
Parameter list | C01407
1208
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01407
C01408
C01409
Parameter | Name:
C01407 | L_Sequencer_1: PSProfil
Data type: UNSIGNED_16
Index: 23168
d
= 5A80
h
From version 12.00.00
L_Sequencer_1: "Positioning" action
Setting range
(min. value | unit | max. value)
0
15
Subcodes
Lenze setting
Info
C01407/1
0
: Pos. action 1: Profile number
C01407/...
...
C01407/50
: Pos. action 50: Profile number
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01408 | L_Sequencer_1: PSStep
Data type: UNSIGNED_16
Index: 23167
d
= 5A7F
h
From version 12.00.00
L_Sequencer_1: "Positioning" action
Setting range
(min. value | unit | max. value)
0
100
Subcodes
Lenze setting
Info
C01408/1
0
: Pos. action 1: Jump destination
C01408/...
...
C01408/50
: Pos. action 50: Jump destination
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01409 | L_Sequencer_1: PS_WD_Time
Data type: UNSIGNED_32
Index: 23166
d
= 5A7E
h
From version 12.00.00
L_Sequencer_1: "Positioning" action
Setting range
(min. value | unit | max. value)
0.000
2147480.000
Subcodes
Lenze setting
Info
C01409/1
0.000
: Pos. action 1: Monitoring time
C01409/...
...
C01409/50
: Pos. action 50: Monitoring time
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000